Edirol V-8 User Manual

Page 91

Advertising
background image

91

Input/output

settings

Intr

oduction

Connections

Basic operation

Switc

hing ima

g

e

s

Eff
ects

BPM sync

External de

vices

Video fader

Appendices

MIDI Implementation

(continued)

Program Change

Status

2nd byte

CnH

ppH

pp = program number: 00H - 7FH (prog.1 - prog.128)

* This selects the input channels. For more detailed information refer to the

Bank Select parameters.

* If a non-selectable Program Change is received, it will be ignored.

Channel Pressure

Status

2nd byte

DnH

vvH

* Just as for Control Change messages, you can make settings in MIDI Setup

to use Channel Pressure messages to control a wide variety of things. For
details on the factory settings, refer to “Settings Transmitted/Received Using
MIDI” (p. 96).

Pitch Bend Change

Status

2nd byte

3rd byte

EnH

llH

mmH

mm, ll = pitch bend value: 00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)

* Just as for Control Change messages, you can make settings in MIDI Setup

to use Channel Pressure messages to control a wide variety of things. For
details on the factory settings, refer to “Settings Transmitted/Received Using
MIDI” (p. 96).

System realtime messages

Active Sensing

Status
FEH

* Once an Active Sensing message is received, the system will begin

monitoring the interval between all subsequent messages. If there is an
interval of greater than approximately 400 ms between messages while
monitoring is occurring, the system will perform reception error processing
and will then stop monitoring the message interval.

Timing Clock

Status
F8H

* Used to synchronize BPM SYNC.

Start

Status
FAH

* Specifies the beginning of the beat for BPM SYNC.

System exclusive messages

Status

Data bytes

Status

F0H

iiH,ddH,...,eeH

F7H

F0H:

System Exclusive Message status

ii = ID number:

An ID number (manufacturer ID) that indicates the
manufacturer to which the exclusive message belongs.
Roland’s manufacturer ID is 41H. ID numbers 7EH and 7FH
are used for Universal Non-realtime Messages (7EH) and
Universal Realtime Messages (7FH) to extend the MIDI
specification.

dd, .. ee = data:

00H-7FH (0-127)

F7H:

EOX (End Of Exclusive)

Data Set 1 (DT1)

This is the message that transfers actual data, and is used to specify data for a
device.

Status

Data bytes

Status

F0H

41H, dev, 00H, 00H, 28H, 12H,

F7H

aaH, bbH, ccH, ddH, ..., eeH, sum

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

dev

Device ID (dev: 00H-FH, factory setting is 10H, 7FH is
Broadcast)

00H

1st byte of model ID (V-8)

00H

2nd byte of model ID (V-8)

28H

3rd byte of model ID (V-8)

12H

Command ID (DT1)

aaH

Upper byte of address

bbH

Address

ccH

Address

ddH

Data: the actual data to be transmitted. Multi-byte data is
transmitted in the order of the address

:

:

eeH

Data

sum

Checksum

F7H

EOX (End Of Exclusive)

Status

Data bytes

Status

F0H

41H, dev, 00H, 51H, 12H,F7H
aaH, bbH, ccH, ddH, ..., eeH, sum

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

dev

Device ID (dev: 00H-FH, factory setting is 10H, 7FH is
Broadcast)

00H

Upper byte of model ID (V-Link message)

51H

Lower byte of model ID (V-Link message)

12H

Command ID (DT1)

aaH

Upper byte of address

bbH

Address

ccH

Address

ddH

Data: the actual data to be transmitted. Multi-byte data is
transmitted in the order of the address.

eeH

Data

sum

Checksum

F7H

EOX (End Of Exclusive)

* For details on setting the address, size, and checksum, refer to “Exclusive

message examples and checksum calculation” (p. 96).

* Data that exceeds 256 bytes must be divided into packets of 256 bytes or

less for transmission. If a subsequent “Data Set 1” message is transmitted,
an interval of at least 20 ms must be left between packets.

V-8_e.book 91 ページ 2010年4月16日 金曜日 午後5時14分