RISCO Group ProSYS Version 7.xx User Manual

Page 12

Advertising
background image

12

ProSYS Version 7.XX - Supplementary Instructions

Bus Zone Parameters: iWISE QUAD AM Grade 3

Quick Keys Parameter

Default

Range

[2][0][3][zz]
[1]

LEDS

On

Defines the LEDS operation mode.

[2][0][3][zz]
[1] [1] to [2]

LEDS Options

1) Off - Disables the LEDS operation.
2) On – Enables the LEDS operation.

[2][0][3][zz]
[2]

Sensitivity

Normal

Defines the sensitivity of the detector (PIR).

[2][0][3][zz]
[2] [1]to[2]

Sensitivity Options

1) Low 2) High

[2][0][3][zz]
[3]

Anti-Mask

Enable

Defines the operation of Anti Masking detection.

[2][0][3][zz]
[3] [1]to[2]

Anti-Mask Options

1) Disable 2) Enable and behaves according to the settings defined
in quick keys [2][0][3][zz][4] .

[2][0][3][zz]
[4]

Arm/Disarm

No

Defines the operation of the anti masking feature while the detector
is armed or disarmed.

[2][0][3][zz]
[4][1]

Arm/Disarm Options

1) No – When detector is armed or disarmed Anti-mask behaves
according to the settings defined in quick keys [2][0][3][zz][3]
2) Yes – When detector is armed Anti-mask is disabled. When
detector is disarmed Anti-mask behaves according to the settings
defined in quick keys [2][0][3][zz][3].

[2][0][3][zz]
[5]

Self Test

Remote

Used to test the detection technologies. In the event of a failed test, a
Self Test Trouble is created.

[2][0][3][zz]
[5][1]

Remote (manual)

The remote self test is performed by the system when a user
manually selects the Diagnostics option from the Maintenance menu
via the ProSYS User Functions menu.

[2][0][3][zz]
[5][2]

Local (automatic)

Once an hour, the detector automatically checks that the detector’s
channels are functioning properly.

Advertising