RISCO Group ProSYS Version 7.xx User Manual

Page 3

Advertising
background image

ProSYS Version 7.XX - Supplementary Instructions

3

Introduction

ProSYS now provides Freedom of Communication - locally between the panel
and the detectors, install detectors serially on the Bus, in star/relay connection or
wirelessly - and remotely via IP, GSM/GPRS or Fast PSTN.
This document describes the following improvements and changes in the ProSYS
version 7.xx due to market requirements and quality improvements:
x Triple EOL Zone Termination and TEOL Zone Expanders
x Fast PSTN modem – 2400 Bps
x Bus Zone Expander for installing up to 128 Bus detectors
x iWISE Bus detectors (Grade 2 and Grade 3) with extra zone input
x Bus detector naming conventions
x Monitoring Station polling via IP and GPRS
x Proximity Anti-Mask setting for WatchOUT DT Version B
x Output activation using a Proximity Tag
x SMTP user and password parameters for email

Please follow the instructions below and refer to the indicated documents for a
detailed description of all the software changes.

Triple End Of Line (TEOL) – New Zone Termination

The Triple End of Line (TEOL) termination type has been added to the zones in
the ProSYS system. TEOL termination is available for zones on the PCB main
board, on the new zone expanders and on the relay input zones on iWISE Bus
detectors.

TEOL uses normally-closed (NC) contacts in a zone to distinguish between
alarm, tamper condition and fault/AM condition using 4.7 K

ȍ +6.8 Kȍ + 12 Kȍ End-of-

Line resistors.