RISCO Group ProSYS Version 7.xx User Manual

Page 8

Advertising
background image

8

ProSYS Version 7.XX - Supplementary Instructions

b. Select the zone that the Bus Zone was assigned to and press

/

.

c.

Use the following tables to configure the parameters for the relevant
iWISE Bus detector.

Bus Zone Parameters: iWISE DT Grade 2

Quick Keys Parameter

Default

Range

[2][0][3][zz]
[1]

LEDS

On

Defines the LEDS operation mode.

[2][0][3][zz]
[1] [1] to [2]

LEDS Options

1) Off - Disables the LEDS operation.
2) On – Enables the LEDS operation.

[2][0][3][zz]
[2]

MW (Microwave) Range

Trimmer

Defines the microwave channel range.

[2][0][3][zz]
[2] [1] to [7]

MW Range Options

1) Minimum 2) 25% 3) 50% 4) 65% 5) 85% 6) Maximum 7) Trimmer
(MW is defined by the trimmer setting on the PCB)

[2][0][3][zz]
[3]

ACT

No

Defines the Anti-Cloak™ Technology (ACT) operation mode.

[2][0][3][zz]
[3] [1] to [2]

ACT Options

1) No - Disables the ACT mode.
2) Yes – Enables the ACT mode.

[2][0][3][zz]
[4]

Automatic Microwave Bypass

No

Defines whether the MW channel will be bypassed or not while the
detector identifies trouble in the MW channel.

[2][0][3][zz]
[4] [1] to [2]

Automatic Microwave Bypass Options

1) No - While detecting a problem in the MW channel it is not
bypassed. Alarm condition cannot be established until the MW
channel is fixed.
2) Yes - Switches the detector to operate only in PIR mode in case of
MW trouble.

[2][0][3][zz]
[5]

Green Line

Yes

A feature that follows environmental guidelines by avoiding surplus
emission. This feature defines the activation of the microwave
channel while the system is disarmed.