RISCO Group ProSYS Version 7.xx User Manual

Page 14

Advertising
background image

14

ProSYS Version 7.XX - Supplementary Instructions

System: Controls

Quick Keys Parameter

Default

Range

[1][2][37]

Prox AM=Tamper

No

Used to determine the operation of the proximity anti masking
detection.
Yes: Proximity anti mask detection will activate the tamper alarm.
No: Proximity anti mask detection will be regarded as a trouble
event.
Note that this parameter is new and replaces the VBR=Tamper
parameter that once used the same quick key sequence.
Note that Proximity AM operates for approximately 2.2 seconds
when the detector is approached in close proximity.

Utility Output Operation Using Proximity Tag

A Utility Output that is defined as “Follow Code” can now also be activated when
a proximity tag is presented to a proximity key reader or a proximity keypad.

ACM Supported in ProSYS 16 and ProSYS 40

The Advanced Communication Module (ACM) that was previously supported only
in ProSYS 128 is now supported in the ProSYS 16 and ProSYS 40 models.

New SMTP User and Password Parameters

Quick Keys Parameter

Default

Range

[5][7][5][6] SMTP User Name – New Parameter

21 characters

This is a new ACM E-Mail parameter that defines the user name that
the SMTP server requires for authentication when defined as such by
the IT department.

[5][7][5][7] SMTP Password – New Parameter

21 characters

This is a new ACM E-Mail parameter that defines the password that
the SMTP server requires for authentication when defined as such by
the IT department.

New Feature - MS Polling by IP/GPRS

Quick Keys Parameter

Default

Range

[5][0][4]

MS Polling by IP network

IP Primary

This parameter checks connectivity between RISCO Group's IP/GSM
Receiver software and the ProSYS panel by sending polling signals
from the ProSYS ACM via the IP channel. Ensure that the IP channel
has been configured properly in the IP/GSM Receiver software.
The information regarding which MS is to be used to perform the
polling is defined according to the MS report split for “urgent events”.
The time intervals for performing the polling with each MS is defined
under the IP Primary, Secondary and Backup parameters.

Advertising