Chapter 5 Specifications

5-4

DP800 User’s Guide

Mechanical
Dimensions

239mm(W) x 157mm(H) x 418mm(D)

Weight

DP832: 10.5kg

DP831: 9.75kg

DP821: 10.0kg

DP811: 10.3kg

Power
AC Input

(50Hz-60Hz)

100Vac±10%, 115Vac±10%, 230Vac±10% (maximum 250Vac)

Maximum Power

DP832: 521VA

DP831: 416VA

DP821: 450VA

DP811: 503VA

I/O
USB Device

1

USB Host

1

LAN

1 (Option)

RS232

1 (Option)

Digital IO

1 (Option)

USB-GPIB

1 (Option, extend a GPIB interface using the USB-GPIB interface

converter)

Rear Output Interface 1 (only for DP811)

Environment
Cooling Method

Fan Cooling

Working Temperature 0℃ to 40℃
Storage Temperature

-40℃ to 70℃

Humidity

5% to 80% relative humidity

Altitude

Below 1500m

Note

[1]

: The accuracy param eters are acquired via calibration under 25℃ after 1-hour warm-up.

Note

[2]

: The maximum time required for the output to change accordingly after receiving the

APPLy and SOURce commands.

Note

[3]

: The variation of the output within 8 hours after 30-minute warm-up when the load circuit

and environment temperature are constant.