Table d-2. ciil error messages, Figure d-8. sta — status command – KEPCO TMA VXI-27 User Manual

Page 68

Advertising
background image

TMA VXI-27 101602

D-5

FIGURE D-8. STA — STATUS COMMAND

Syntax:

STA

Function:

Causes power supply to return operating status to controller.

Description:

This operator commands the power supply to report its present operating status. Status is reported in
the form of a message (character string) as defined below. Any catastrophic error conditions (indicated
by * in the table below) which exist will be reported, until the error condition is corrected. As required
by CIIL, all error messages begin with an ASCII “F” (Fault) followed by a 2 digit code, “07” (Halt). The
code that follows (SCSnn) indicates the type of device and the channel number. The next 3 digit code
describes the nature of the fault: “DEV” for device related errors or “MOD” for non-device errors, such
as syntax.

TABLE D-2. CIIL ERROR MESSAGES

ERROR MESSAGE

EXPLANATION

F07 DCSnn DEV Power Loss

The power supply has lost its input power. *

F07 DCSnn DEV Crowbarred

(MAT, MBT)

A shutdown occurred due to overvoltage or overcurrent. *

F07 DCSnn DEV Device Turned Off (BOP)

F07 DCSnn DEV Output Fault (MST)

F07 DCSnn DEV Over Temperature

A shutdown occurred due to thermal causes. *

F07 DCSnn DEV Overload

The voltage or current limit point was exceeded. *

F07 DCSnn DEV Voltage Fault

The output voltage is not within limits (voltage mode). *

F07 DCSnn DEV Current Fault

The output current is not within limits (current mode). *

F07 DCSnn DEV Relay Not Opened

The power relay failed to open. *

F07 DCSnn DEV Relay Not Closed

The power relay failed to close. *

F07 DCSnn DEV Polarity Error

The output polarity is not correct. *

F07 DCSnn DEV

Load Path Fault

Open or miswired load or error sense leads detected. *

F07 DCSnn MOD Invalid Command

Improper syntax was used. **

F07 DCSnn DEV Not Ready

The output voltage or current has not settled. **

F07 DCSnn DEV Device Not Present

The specified power supply was not present during power up or
during the last DCL. **

F07 DCSnn DEV Device Not Responding

The power supply has failed to communicate to the controller.
**

F07 DCSnn DEV Invalid Voltage Range

The programmed voltage is outside the power supply's range.
**

F07 DCSnn DEV Invalid Current Range

The programmed current is outside the power supply's range.
**

F07 DCSnn DEV Set Modifier Error

An improper SET command was sent. **

F07 DCSnn DEV Invalid Device ID

The selected channel was not between 1-31. **

*Catastrophic error
**Non Catastrophic error