Enterasys Networks Security Router X-PeditionTM User Manual

Page 426

Advertising
background image

System Alarms and Events

A-4 Alarms/Events, System Limits, and Standard ASCII Table

T1E1

Receiver has Loss of Frame (Yellow
Alarm).

T1/E1 physical port is detecting an OOF alarm.

T1E1

LOF alarm on receiver cleared.

T1/E1 physical port is not detecting an OOF alarm.

T1E1

Transmitting Remote Alarm (Yellow
Alarm).

T1/E1 physical port is transmitting a remote alarm.

T1E1

Transmit Remote Alarm cleared.

T1/E1 physical port is not transmitting a remote alarm.

SYNC_
DRIV

The ISR could not be connected

Driver failed to connect the ISR to the BSP, so it will not start.

SYNC_
DRIV

Init string parse failure

Driver could not parse the initialization string so it will not start.

SYNC_
DRIV

Unrecoverable error

XSR has an un-recoverable error.

SYNC_
DRIV

OS initialization failure

The operating system failed to initialize the driver properly, so the
XSR cannot start.

SYNC_
DRIV

Device not found

XSR could not be found on the PCI bus, so the driver cannot start.

SNMP

Failed to enable SNMP server

Failure to start SNMP server due to failure in the locking mechanism
or the message queue is full.

SNMP

Failed to disable SNMP server

Failure to start SNMP server due to failure in the locking mechanism.

PLATF

System reset from <reason>, <warm|cold>
start

Warm or cold start occurs for the following reasons:
• Default config init: dcfg
• Crash reset: crsh
• CLI reset: cli
• SNMP reset: snmp
• Bootrom reset: btrm
• Software checksum invalid: cksm

PLATF

Failed to initialize sysLog socket

Cannot create socket for sending syslogs.

PLATF

Failed to bind to sysLog port 514

Cannot bind to port 514 for sending syslogs.

ISDN

<BRI c/p>, SPID <spid string> Registered
(CES <1|2)

BRI with a North American switch type successfully registers with the
central office.

ISDN

<BRI c/p>, Unsolicited
SME_TERM_REGISTER_ACK

BRI with a North American switch type registers with the central
office but fails.

ISDN

<BRI c/p>, Registration Failed, Cause
<number>

BRI with a North American switch type registers with the central
office and fails. Causes include: 100 - SPID configuration error, 41 -
Network timeout and 1 - Fit timeout

ISDN

%s Layer 2 Terminal %d is DOWN
%s Layer 2 Terminal %d is UP

Q921 - LAP-D status, UP is normal operation. Terminal is 1 for PRI.
For BRI it may be 1 or 2. 1 for ETSI and NTT. For North America 1
and 2 if two SPIDs are configured.

ISDN

%s Outgoing Call to %s %s Timed Out

For basic-NET3 BRI, XSR was unable to activate the BRI line for an
outgoing call.

ISDN

%s Switch Offers call for BUSY channel
%X

Error condition!

Table A-6 High Severity Alarms/Events (continued)

Module

Message

Description

Advertising