Enterasys Networks Security Router X-PeditionTM User Manual

Page 428

Advertising
background image

System Alarms and Events

A-6 Alarms/Events, System Limits, and Standard ASCII Table

ETH1_
DRIV

The ISR could not be connected

This is internal configuration alarm occurs because the interrupt
service routine (ISR) cannot be connected to the FastEthernet 2
interface/driver, rendering FastEthernet port 2 unavailable.

ETH1_
DRIV

Init string parse failure

This internal configuration alarm is due to the driver being unable to
parse its initialization string, rendering FastEthernet port 2
unavailable.

ETH1_
DRIV

Unrecoverable error

The FastEthernet 2 chip on the motherboard has severe problems -
a catastrophic failure. The most likely cause is a hardware failure.
When this alarm occurs, FastEthernet port 2 is unavailable.

ETH1_
DRIV

OS initialization failure

This internal configuration alarm occurs because the operating
system initialization of the driver/interface cannot be completed,
rendering FastEthernet port 2 unavailable.

ETH1_
DRIV

Device not found

Most likely this occurs due to a hardware failure - the FastEthernet 2
chip cannot be found on the PCI bus (of the motherboard). When this
occurs, FastEthernet port 2 is unavailable.

ETH0_
DRIV

The device is stuck in reset

The FastEthernet 1 chip on the motherboard has severe problems -
it cannot come out of reset and the FastEthernet 1 driver/interface
cannot be started. The most likely cause is a hardware failure. When
this alarm occurs, FastEthernet port 1 is not available.

ETH0_
DRIV

The ISR could not be connected

This internal configuration alarm occurs because the interrupt
service routine (ISR) cannot be connected to the FastEthernet 1
interface/driver, rendering FastEthernet port 1 unavailable.

ETH0_
DRIV

Init string parse failure

This internal configuration alarm occurs because the driver could not
parse its initialization string, rendering FastEthernet port 1
unavailable.

ETH0_
DRIV

OS initialization failure

This internal configuration alarm occurs because the operating
system initialization of the driver/interface cannot be completed,
rendering the FastEthernet 1 interface unavailable.

CLI

Failed to create session for web access

Failure to start session for the Web.

CLI

Failed to create session for console access Failure to start session for the Web.

CLI

Failed to create session for telnet access

Failure to start session for console.

CLI

Failed to create session for telnet access

Failure to start session for Telnet.

CLI

Failed to enable Telnet server

Cannot start Telnet server because socket open failed.

CLI

Failed to enable Telnet server

Cannot start Telnet server because socket bind failed.

CLI

Failed to enable Telnet server

Cannot start Telnet server because socket listen failed.

CLI

Failed to enable Telnet server

Failure to enable the Telnet server.

CLI

CLI Config mode released by user
<username>

A user exits Configuration mode.

CLI

CLI Config mode released by user
<username>

An unknown user exits Configuration mode.

CLI

CLI config mode released by startup-config Configuration mode is released when the startup-config script

finishes execution.

Table A-6 High Severity Alarms/Events (continued)

Module

Message

Description

Advertising