Enterasys Networks Security Router X-PeditionTM User Manual

Page 427

Advertising
background image

System Alarms and Events

XSR User’s Guide A-5

ISDN

Incoming Call <BRI | Serial card/
port:channel> Connected to <calling no.>
Unknown Call

An incoming call connected for test purposes will be disconnected
within 30 seconds.

ISDN

North American BRI Interface %d requires
SPID configuration

Configuration error.

ISDN

Call <BRI | Serial card/port:channel>
Connected to <called_no.> Outgoing test
CALL

A test call is placed from the console.

ISDN

Call <BRI | Serial card/port:channel>
Disconnected from <number> <Outgoing
test CALL | Unknown Call> Cause <passed
from central office>

A test call is disconnected due to the standard ISDN cause. E.g. 16:
normal clearing, 18: user does not answer.

ISDN

No Channel Available <destination name>

ISDN line was over subscribed.

ISDN

_FILE _LINE Out of memory

Unable to allocate memory.

ISDN

ISDN panic!!

Unable to create ISDN object.

ISDN

_FILE _LINE Out of memory

Unable to allocate memory.

ISDN

_FILE _LINE Out of memory

Unable to allocate memory.

ISDN

_FILE _LINE unexpected value

Unexpected message received.

ISDN

Interface BRI, changed state to up

Port has changed to Up state.

ISDN

Interface BRI, changed state to down

Port has changed to Down state.

FR

Serial a/b:d.e, started

Output from the no shutdown command.

FR

Serial a/b:d.e, shutting down

The interface has been manually shut down.

FR

Serial a/b:d.e, station UP, DLCI nnnn

The network reports the station is up.

FR

Serial a/b:d.e, station DOWN, DLCI nnnn

The network reports the station is up.

FR

Serial a/b:d cannot establish LMI, port is
down

The network has not been responding for 5 minutes. You should
check the connection.

FR

Serial a/b:d LMI - port DOWN

The LMI is reporting the port is Down.

FR

Serial a/b:d LMI - port UP

The network is reporting the port is Up.

FR

Serial a/b:d.e Config Error Aggregate CIR
nnnn greater than measured speed nnn -
CIR Assist is DISABLED

The total configured CIR exceeds the speed of the link and cannot
guarantee CIR. Assist will not be operational.

ETH1_
DRIV

The device is stuck in reset

The FastEthernet 2 chip on the motherboard has severe problems -
it cannot come out of reset and the FastEthernet 2 driver/interface
cannot be started. The most likely cause is a hardware failure. When
this alarm occurs, FastEthernet Interface 2 is not available.

ETH1_
DRIV

The device TX/RX is stuck in reset

The FastEthernet 2 chip on the motherboard has severe problems -
either the transmitter or receiver cannot come out of reset and the
FastEthernet 2 driver/interface cannot be started. The most likely
cause of this alarm is a hardware failure, rendering FastEthernet port
2 unavailable.

Table A-6 High Severity Alarms/Events (continued)

Module

Message

Description