Enterasys Networks Security Router X-PeditionTM User Manual

Page 433

Advertising
background image

System Alarms and Events

XSR User’s Guide A-11

Refer to the table below for all Low severity alarms and events reported by the XSR. All of the
following messages are USER_LEVEL facility except for those in

bold

text which are

SECURITY_LEVEL.

ETH0_
DRIV

PHY write operation unsuccessful

The PHY chip on the FastEthernet 1 interface has had an error (other
than time-out) while processing a write request. When this occurs, port
functionality may or may not be affected. The port will still be available,
but its functionality may be diminished. The cause of this alarm is most
likely HW failure.

DIAL

Dial muxIoctl call fail

Failure of the serial driver of the physical port connected to the
modem.

DIAL

Modem on intf # is not responding

The modem is not connected or powered on.

DIAL

Invalid init string for modem on intf #

The modem does not recognize the initialization string. You should
check the modem specification for a proper setup.

DIAL

Number busy for modem on intf #

The remote site dialed number is busy.

DIAL

No dial tone for modem on intf #

There is no dial tone for the modem PSTN line.

DIAL

No carrier for modem on intf #

The remote modem is not present at the site called by the local
modem.

DIAL

No answer for modem on intf #

The remote modem is not configured for autoanswering.

DIAL

Connection dropped for modem on intf#s

The phone line connection is disconnected by the PSTN.

DIAL

Hangup fail for modem on intf #

Failure of the disconnect from the phone line command to the modem.

DIAL

Connection closed for modem on intf #

The phone line disconnect command is successful.

DIAL

Dialup connection opened for modem on
intf #

The modem has successfully built a phone line link with the remote
site.

CLI

Failed to create session for Telnet access

Telnet session could not be created at this time.

CLI

Unrecognized parameter <parameter
string> at line <line #> in <file>

Invalid parameters from initialization configuration file during boot
process. This file is different from the startup.cfg.

FR

serial a/b:d, started

Result from

no shutdown

command

FR

serial a/b:d, shutting down

Shutdown

command

FR

serial a/b:d, station up, DLCI nnn

FR

serial a/b:d, unknown LMI message

Cannot decode the received LMI Message.

FR

Serial a/b:d, dlci nn, No InVArp response
from remote

The remote peer is not responding to Inverse ARP requests.

FR

Max. packet size based on CIR,BC,BE is
less than 1514 bytes

Table A-7 Medium Severity Alarms/Events (continued)

Module

Message

Description

Table A-8 Low Severity Alarms/Events

Module

Message

Description

T1E1

Receiver has Loss of Signal (Red Alarm).

Indicates that T1/E1 physical port is detecting LOS Alarm.

T1E1

LOS alarm on receiver cleared.

Indicates that T1/E1 physical port is not detecting LOS Alarm.

Advertising