Control Using the TALLY/GPI Connector

Inputting a Control Signal

To operate the V-600UHD remotely using control-signal input, you

first assign the function to a GPI channel (1 through 8).

1.

Select the [MENU] button

&

“System”

&

“GPI,” and

press the [VALUE] knob.

2.

Use the [VALUE] knob to specify the function to

assign to the GPI channel (1 through 8).

&

Details on menu items: p. 45

3.

Press the [MENU] button to quit the menu.

When a control signal is input from an external source, the

assigned function is executed. The GPI trigger is fixed at the

trailing edge (low: On).

Outputting a Tally Signal

A tally signal is output from the connector pin corresponding to the

video channel being output, also including video composition and

transition effects.

Pin layout

5 4 3 2 1

15

16

17

18

19

20

21

22

23

24

25

14

10

11

12

13

9 8 7 6

DB-25 type (female)

Tally output

Trigger method

Open collector

Maximum input

12 V/200 mA

Control input

Trigger method

No-voltage contact (make-contact) triggering

Contact capacity

DC 24 V 0.1 A or higher

Input method

Photocoupler

Pin assignments

Pin No.

Function

Pin No.

Function

1

TALLY 1 PGM

14

TALLY 7 PST

2

TALLY 1 PST

15

TALLY 8 PGM

3

TALLY 2 PGM

16

TALLY 8 PST

4

TALLY 2 PST

17

GND

5

TALLY 3 PGM

18

GPI 1

6

TALLY 3 PST

19

GPI 2

7

TALLY 4 PGM

20

GPI 3

8

TALLY 4 PST

21

GPI 4

9

TALLY 5 PGM

22

GPI 5

10

TALLY 5 PST

23

GPI 6

11

TALLY 6 PGM

24

GPI 7

12

TALLY 6 PST

25

GPI 8

13

TALLY 7 PGM

You can operate the V-600UHD remotely from an external device by inputting a GPI control signal via the TALLY/GPI connector.
And you can output a tally signal from the TALLY/GPI connector.

Specification of the TALLY/GPI Connector