5. Reach in through the opening, push the spring-loaded base down (1) with one hand, and

pull the separation pad up (2) with the other hand.

6. With one hand, position the new separation pad in the slot that held the previous

separation pad (1). With the other hand, reach through the input tray opening and push
down the spring-loaded base (2).

Note

The tab on the right is larger, which helps you position it correctly.

7. Snap both sides of the separation pad firmly into place.

CAUTION

Make sure that the separation pad is straight and that no space exists between the separation
pad and the spring-loaded base. If the separation pad is not straight or you see space on one
side, remove the separation pad, make sure that the larger tab is on the right, reinsert the
separation pad, and snap both sides into place.