Termination locations, Warning, A. vent termination minimum clearances – Heat & Glo Fireplace BRAVO 704-902 User Manual

Page 10

Advertising
background image

Heat & Glo • Bravo • 704-902 Rev. F • 10/08

10

A. Vent Termination Minimum Clearances

Fire Risk.

Explosion Risk.

Maintain vent clearance to combustibles as
specifi ed.

• Do not pack air space with insulation or other

materials.

Failure to keep insulation or other materials
away from vent pipe may cause fi re.

Roof Pitch

H (Min.) Ft.

Flat to 6/12...........................................................1.0*
Over 6/12 to 7/12 .................................................1.25*
Over 7/12 to 8/12 .................................................1.5*
Over 8/12 to 9/12 .................................................2.0*
Over 9/12 to 10/12 ...............................................2.5
Over 10/12 to 11/12 .............................................3.25
Over 11/12 to 12/12 .............................................4.0
Over 12/12 to 14/12 .............................................5.0
Over 14/12 to 16/12 .............................................6.0
Over 16/12 to 18/12 .............................................7.0
Over 18/12 to 20/12 .............................................7.5
Over 20/12 to 21/12 .............................................8.0

Figure 4.1

Figure 4.2 Minimum height from roof to lowest discharge
opening

4

4

Termination Locations

Measure horizontal clearances from this surface.

Measure vertical clearances from this surface.

Figure 4.3 Multiple Vertical Termination

Figure 4.2 specifi es minimum vent heights for various
pitched roofs.

(See Figure 4.4 for specifi c clearances)

* 3 foot minimum in snow regions

HORIZONTAL

OVERHANG

VERTICAL

WALL

GAS DIRECT VENT
TERMINATION CAP

12

X

ROOF PITCH

IS X/ 12

LOWEST

DISCHARGE

OPENING

2 FT.

MIN.

20 INCHES MIN.

H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING

C

A

GAS

TERMINATION

B

GAS, WOOD OR FUEL

OIL TERMINATION

WARNING

Gas

Termination

Wood & Fuel Oil

Termination

Comments

A

6 in.

20 in. min.

Horizontal distance between terminations

B

20 in.

24 in. min.

Distance to perpendicular wall

C

18 in.

18 in.

Vertical distance between terminations

Fire Risk.
Explosion Risk.
Inspect external vent cap regularly.
• Ensure no debris blocks cap.
• Combustible materials blocking cap may

ignite.

• Restricted air fl ow affects burner operation.

WARNING