background image

Heat & Glo • Bravo • 704-902 Rev. F • 10/08

30

CAUTION

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Shock hazard.
• Replace damaged wire with type 105

O

C

rated wire.

• Wire must have high temperature insulation.

WARNING

IGNITION
MODULE

(3V)

VALVE

LOW VOLTAGE

PLUG-IN

3V TRANSFORMER

NEUTRAL

HOT

GROUND

FLAME SPARKER/

SENSOR

REMOTE

CONTROL

SEE NOTE 1

VALVE

TRANSFORMER
3 VAC

ORG

WHT

ORG

GRN

ON/OFF

WALL SWITCH

BRN

BRN

BLK

RED

THERMOSTAT
WIRE ASSEMBLY
2045-045

REMOTE JUMPER
WIRE

PLUG IN

IGNITION MODULE 3 VAC

INTERMITTENT PILOT IGNITOR

BLACK WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE HOT SIDE

WHITE WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE NEUTRAL SIDE

GROUND TO
FIREPLACE
CHASSIS

LOW VOLTAGE
SEE NOTE 1.

NOTE 1: IGNITION MODULE, VALVE, PILOT AND WALL SWITCH OPERATE ON 3 VOLTS.
120 VAC IS REQUIRED AT JUNCTION BOX UNLESS EQUIPPED WITH BATTERY BACK-UP.

Figure 10.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram