Warning, D. vent diagrams – Heat & Glo Fireplace BRAVO 704-902 User Manual

Page 13

Advertising
background image

Heat & Glo • Bravo • 704-902 Rev. F • 10/08

13

Figure 5.3

Figure 5.4

WARNING

1. Top Vent - Horizontal Termination

One Elbow

Two Elbows

Note: When installing the TAOS surround
and venting with one elbow, a straight sec-
tion of venting (30 in. minimum) MUST be
attached directly to starting collars on unit.

Note:

V

1

MUST be a minimum

of 3 feet unless using the TAOS
surround. For TAOS surround, V

1

minimum MUST be 30 in.

V

1

Minimum

H

1

Maximum

3 ft.

0.9 m

2 ft.

0.6 m

4 ft.

1.2 m

4 ft.

1.2 m

5 ft.

1.5 m

6 ft.

1.8 m

12 ft.

3.7m

20 ft.

6.1 m

V

1

+ H

1

= 40 ft. (12.2 m) Maximum

H

1

= 20 ft. (6.1 m) Maximum

Note: The fi rst elbow used MUST always
be DVP90ST.

Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.

Note: The first elbow used
MUST always be DVP90ST.

V

1

Minimum

H

1

+ H

2

Maximum

3 ft.

0.9 m

2 ft.

0.6 m

4 ft.

1.2 m

4 ft.

1.2 m

5 ft.

1.5 m

6 ft.

1.8 m

12 ft.

3.7 m

20 ft.

6.1 m

V

1

+ H

1

+ H

2

= 40 ft. (12.2 m) Maximum

H

1

+ H

2

= 20 ft. (6.1 m) Maximum

D. Vent Diagrams

Advertising