Warning caution, Vent information and diagrams – Heat & Glo Fireplace BRAVO 704-902 User Manual

Page 12

Advertising
background image

Heat & Glo • Bravo • 704-902 Rev. F • 10/08

12

Fire Hazard.

Explosion Risk.

Asphyxiation Risk.
Do NOT connect this gas appliance to a
chimney fl ue serving a separate solid-fuel or
gas burning appliance.

• Vent this appliance directly outside.

• Use separate vent system for this appliance.

May impair safe operation of this appliance or
other appliances connected to the fl ue.

WARNING

CAUTION

ALL vent confi guration specifi cations MUST be followed.

• This product is tested and listed to these

specifi cations.

• Appliance performance will suffer if specifi cations are

not followed.

Diagonal runs have both vertical and horizontal vent as-
pects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect (see
Figure 5.1).

Two 45

0

elbows may be used in place of one 90

0

elbow. On

45

0

runs, one foot of diagonal is equal to 8.5 inches hori-

zontal run and 8.5 inches vertical run. A length of straight
pipe is allowed between two 45

0

elbows (see Figure 5.1).

Figure 5.1

C. Measuring Standards

Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards.

1. Pipe measurements are shown using the effective length

of pipe (see Figure 5.2).

2. Measurements are made from the appliance outer wrap,

not from the standoffs.

3. Horizontal terminations are measured to the outside

mounting surface (fl ange of termination cap) (see Figure
4.1).

4. Vertical terminations are measured to bottom of termina-

tion cap.

5. Horizontal pipe installed level with no rise.

Figure 5.2 DVP Pipe Effective Length

Effective

Height/Length

DVP4 4
DVP6 6
DVP12 12
DVP24 24
DVP36 36
DVP48 48
DVP6A

3 to 6

DVP12A

3 to 12

DVP12MI 3

to

12

DVP24MI 3

to

24

Length/
Inches

Pipe

Symbol

Description

V

1

First section (closest to appliance of vertical length

V

2

Second section of vertical length

H

1

First section (closest to appliance) of horizontal length

H

2

Second section of horizontal length

Horizontal

Vertica l

8-1/2 in.

8-1/2 in.

12 in.

5

5

Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in
the vent diagrams.

B. Use of Elbows

Advertising