33

C. Finishing Styles

This model has multiple installation and fi nishing options.
The following section describe fi ve basic installations.

WARNING

Fire Risk.
1/2 inch non-combustible board installed on front
face of fi replace MUST remain if using combustible
fi nishing materials.

CAUTION

Finishing materials cut inside the provided template will
cause the door to not fi t.

Figure 11.4 Flush wall installation

A cardboard template is printed on unit shipping
carton and may be used to help cut drywall or other
fi nishing materials. Simply cut along line and use it as a
template.

• Finishing materials may be fastened or secured to unit

below the glass/front opening.

• Unit is installed using framing dimensions found in

Figure 3.2.

• Do not use nailing tabs provided on unit sides for Option

A.

• Nailing tabs are attached to the top of the unit. Install

nailing tabs using screws on upper unit sides (see
Figure 11.3).

• This places unit back 1/2 inch from framing studs such

that drywall or other material can be brought directly
across non-combustible board up to fi nish edge trim.

OPTION A: Flush Wall Finish

Kiva-style fi nished in a straight wall (see Figure 11.4).

Figure 11.5

• Drywall or other fi nishing materials may be fi nished all

the way up to the fi nishing edge trim or unit front face,
but MUST NOT extend inside of fi nishing edge trim.

• Framing depth increases from that shown in Figure

3.2, (Dimension C). Dimension C will vary depending
on the depth of the desired kiva-style arch (see Figure
11.5).

• Once depth of desired kiva-style arch is determined

(minimum of 3-3/32 inches and maximum 5 inches),
add that to Dimension C from Figure 3.2. Level, set
and secure fi replace using nailing tabs provided on
fi replace sides. Secure with screws or nails into BACK
of framing studs.

• Kiva-style arch dimensions: Maximum depth

equals 5 inches (includes finish wall surface).
Minimum depth equals 3-3/32 inches.

5 INCH

MAXIMUM

DEPTH

INCLUDING

WALL FINISH

MATERIAL

OPTION B: Kiva-style Arch

The second installation option requires the construction
of a kiva-style arch. This option recesses the unit into the
wall such that construction of a hearth is not necessary
(see Figure 11.5).

Note: A 1/2 inch clearance must be maintained between
combustible materials and the front face of the fi replace.

Advertising