Temperature control of appliances, Temperature alarms, Humidity – Home Automation SECURITY SYSTEM User Manual

Page 36: Status

Advertising
background image

Temperature Control of Appliances

You can control appliances connected to X-10 and ALC modules (such as a ceiling fan) using the Button feature of the OmniLT.
For example, the ceiling fan can be programmed to come on if the temperature goes above the High temperature (a programming
example to set this up is shown in the Programming section).

High and Low setpoints for temperature zones are changed the same way as the PESM. However, on/off control of the ceiling
fan is done from the 1 (CONTROL) menu. Use the ceiling fan's unit number to turn it On or Off. The PESM and the ceiling fan
are linked together by a button program.


Temperature Alarms


Temperature sensors can be used to signal that a temperature (in a special room, like a greenhouse or wine cooler) has gotten too
high or too low. If the temperature in this zone goes above the High setpoint or below the Low setpoint, the console beeper is
activated (inside and outside sirens are not activated) and the central station and/or voice dialer is called.

The High and Low setpoints are changed as described for the PESM. Use the zone number that the temperature sensor is
connected to in place of the unit number.

NOTE: Setting a High or Low temperature to 0 takes it out of service.


Humidity


The Model 31A00-2 Indoor/Outdoor Temperature and Humidity Sensor is used for sensing indoors temperature and/or reporting
the relative humidity from 0 to 100 percent or for sensing the outdoor temperature and/or reporting the outdoor relative humidity.

High and low humidity limits can be set for taking action (i.e. turning on the bathroom vent fan, running a/c in de-humidification
mode, turning on humidifier in heating mode, etc.) or reporting high or low humidity conditions in homes, greenhouses, wine
cellars, coolers, humidors, etc. Controlling humidity is particularly helpful in combating the growth of mold in vulnerable areas
of the home, such as bathrooms, basements, attics, etc.

The humidity level (0-100%), the low humidity setting, and high humidity setting can be viewed and modified using the
temperature menu. To enter the temperature menu, from the top-level display or from the main menu, press the 5 (TEMP) key.
The humidity zone can be specified by entering the zone number followed by the ' # ' key, or by pressing the arrow keys to scroll
through the list of temperature and humidity zones. Press the ' # ' key when the desired temperature zone is shown.

INDOOR: HUMI: 75

LOW: 10 HIGH: 90


Status


The Status function is used to display the status of various items in the system. To enter the status menu, from the top-level
display or the main menu, press the 6 (STATUS) key on the console keypad.

STATUS

1=CTRL 2=ZONE 3=SUN


4=TEST

5=TEMP

6=ENERGY


1 = CTRL (CONTROL UNITS)


The Control Status menu allows you to view and scroll through the status of each control unit and to configure HLC and UPB
devices. To enter the Unit menu, from the Status menu, press the 1 (CTRL) key in the console keypad. The system will display:

DEN

LAMP

STATUS OFF

32

Advertising