FORMAT NUMBER

DESCRIPTION


STANDARD

0

Preset Dim Command (X-10, X-10 Pro, Leviton, PCS, etc.)

EXTENDED

1

Extended Code Level Command (Leviton)

COMPOSE

2

Compose

Mode

(Lightolier's

Compose)

UPB

3

Universal

Powerline

Bus

(open

format)

RADIO

RA

4

Lutron

RadioRA

HAI

LIGHTING

5

HAI

Lighting

Control

(HLC)

CENTRALITE

6

CentraLite

Lighting


The default setting for HC 1 Format is 5 (HLC).


House Code All Off

This feature allows you to choose if the House Code will respond to the “All Off” command. Press the 0 key to select No and the
1 key to select Yes.

HC 1 ALL OFF: 1

0=NO 1=YES


The default setting for HC 1 All Off is Yes.

Notes:


1. When configured, the House Code will affect 2 rooms of HLC lighting (i.e. HC 1 ALL OFF affects Room 1 and 2).

2. When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All Off” does not affect the state of the

installed devices; however, if this setup item is set to “Yes”, OmniLT will change the status of all units on that House Code
to “Off” (even though it doesn’t explicitly send an All Off command to those units). If the “House Code All Off” setup item
is set to “No”, OmniLT will not change the status of units on that House Code.


House Codes All On

This feature allows you to choose if the House Code will respond to the “All On” command. Press the 0 key to select No and the
1 key to select Yes.

HC 1 ALL ON: 1

0=NO 1=YES


The default setting for HC 1 All On is Yes.

Notes:


1. When configured, the House Code will affect 2 rooms of HLC lighting (i.e. HC 1 ALL ON affects Room 1 and 2).

2. When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All On” does not affect the state of the

installed devices; however, if this setup item is set to “Yes”, OmniLT will change the status of all units on that House Code
to “On” (even though it doesn’t explicitly send an All On command to those units). If the “House Code All On” setup item is
set to “No”, OmniLT will not change the status of units on that House Code.


Time Clocks

There are three time clocks in the system are used to conditionalize programs. They are used solely to define time periods during
the week when certain programs should be enabled or disabled to execute.

TIME CLOCK 1 ON
TIME CLOCK 1 OFF

Specify the On and Off times for each Time Clock - See Set Up Codes.

TIME CLOCK 1 ON TIME: