Appendix a - specifications – Home Automation SECURITY SYSTEM User Manual

Page 76

Advertising
background image

APPENDIX A - SPECIFICATIONS


Size:

Controller: 9.1W x 12.1H x 3.5D

Console:

4.6W x 4.5H x 1.2D


Weight:

Controller: approx. 4.5 lb.

Console:

approx. 0.5 lb.


Operating

32 - 122 degrees F (0 - 50 degrees C)

Ranges:

10 - 95 % relative humidity, non-condensing


Power:

120 VAC, 60 Hz, 60 watts


Transformer:

16.5 VAC, 40 VA, 50/60 Hz


Battery:

Sealed

Rechargeable

Lead-Acid,

12

volts


Bell Fuse:

Polyfuse: 1.35 A


Device Fuse:

Polyfuse: .9 A


Output Fuse:

Polyfuse: .3 A


Battery Fuse:

Polyfuse: 2.5 A


Polyfuses are permanent fuses that do not need replacement.

Nominal Output Voltage: 10-13.8 VDC

Low Voltage Cut Out:

approx. 9 VDC


Typical Current Consumption at Nominal Voltage:


Controller:

105

mA

Console:

backlight off, 35 mA

backlight on, 100 mA



CONTROLLER OUTPUTS

UL RATINGS

MAXIMUM


Devices: AUX 12 VDC, CONSOLE, and OUTPUTS 1 and 2:

200 mA

500 mA


Bell:

BELL

350

mA

1

A


Outputs: OUTPUTS 1 and 2, each, maximum:

100 mA

100 mA


Backup:

Required

battery

backup

hours:

24

hours


Battery:

Recommended

Battery:

7

Ah

14

Ah

72

Advertising