Switch press event buttons (centralite), Edit program command, Program control commands – Home Automation SECURITY SYSTEM User Manual

Page 59

Advertising
background image

Pro-Link determines that a message has been received when:

One or more characters have been received followed by 100 ms of silence

One or more characters followed by a carriage return character are received

One or more characters followed by a line feed character are received

It is not necessary to enter the terminating carriage return or line feed character as part of the message name.

Switch Press Event Buttons (CentraLite)

When a button is pressed on a CentraLite keypad, the "When Switch" program is activated.

Pressing the 9 (SWITCH) key allows you to select the "When Command" for a switch pressed activated event.

You are first prompted to enter the switch number:

SWITCH NUMBER:

1-127


Enter the switch number followed by the ' # ' key.

Edit Program Command

Selecting 2 (CMD), from the Edit Program menu, allows the commanded action for the program to be specified. The following
menu is displayed:

1=CONTROL 2=SECURITY

3=BUTTON 4=ALL

5=TEMP 6=ENERGY
8=MESSAGE


After the command is specified, the display returns to the Edit Program menu:

Program Control Commands

Press the 1 (CONTROL) key to command lights and appliances. Specify the desired command - See Control.

Porch

Light

(Unit

Name)

0=OFF

1=ON

2=DIM

3=BRT

Porch

Light

(Unit

Name)

4=LVL

5=RMP

9=TIM

#=STA


If the selected unit is is configured to use the Compose Format, the second page of the menu is modified to allow Scene
commands. Consequentially, the Level and Ramp Commands are removed from the menu.

Entry

Lights

(Unit

Name)

4=SCN 9=TIM #=STA


If the selected unit is not capable of dim and bright commands, only a single menu is shown.

Porch

Light

(Unit

Name)

0=OFF 1=ON 9=TIM #=STA


If the selected unit is UPB, press 6 (LED) to control an LED on a UPB Keypad.

On the 6-Button Keypad: LED 1 is behind the “On” button, LED 2 is behind the “Off” button, and LED 3-6 is behind the A-D
buttons, respectively. On the 8-button Keypad: LED 1-8 is behind the 1-8 buttons, respectively. For example:

WHEN U1 SW 3:

55