Clearance diagrams - 36” metro, 4metro / legacy series, Dim 36" metro – Heartland 3530 User Manual

Page 7

Advertising
background image

4

Metro / Legacy Series

Dim

36" Metro

G

25 1/2" (65cm)

H

36" (92.5cm)

I

12" (30.5cm)

J

37" (94cm)

K

5 5/8"(14.5cm)

L

2" (5cm)

M

18" (38cm)

N

20" (51cm)

O

6" (6cm) min left and right side

P

13" (33cm)

Q

SPECIFY WIDTH OF HOOD

R

24" (61 cm)

S

30" (76cm) min - 36" (92 cm)

for standard and high back guard

S

1

30" (76 cm) min -

33 1/2" (85cm) max.

for low profile back guard only

T

18" (45cm)

E dg e s o f
co u nte r to p
m u st b e finish e d

G

H

I

J

K

O

cu pb
m u s
26”

o ard d epth

t

not e xce e d

L

M

P

Q

R

S
S

1

N

G as Inle t

A n ti-tip
b ra cket

T

Clearances
• Oven door vents must be 2" from any combustible. Door vents are required on Metro units to allow oven door ventilation.
• Minimum distance between the range and a side wall above the cooking top surface is 6” (see dim "O" in Table 2 below)
• 0” Clearance to the back of the stove may be obtained when installing the appliance against a non - combustible wall or
with the installation of our Splashback Kit. Responsibility for ensuring that the rear wall is non - combustible lies with the
owner or end user. (check local building codes) - if wall behind stove is deemed combustible and our splashback kit is not
installed, then the minimum spacing from the back of stove to nearest combustible wall is 6”

Electrical requirements:
• Electrical hookup must be done by a licenced electrician
• 240 Volts 60Hz 5.6 kW 3 prong plug for U.S. and 4 prong for Canadian installations.
(5 ft-1.5 m power cord included) New installations for the U.S. may require a four prong
plug, please confirm prior to ordering.

Figure 1

Table 1

For proper performance a 900 CFM vent
hood is required on all 36" Metro ranges
to ensure adequate and proper ventilation.
For superior ventilation we recommend
using a 42” hood, however a 36” hood is
adequate.

Note: If range must stand

beside a refrigerator, it is
important for proper air
circulation.There must be at
least 5” (125 mm) of space
between the two appliances.

Table 2

Figure 2

Dim

36" Metro

A

1

28 3/4" (73cm)

to front of stove

A

2

31 1/4" (79cm)

to edge of oven door handle

B

36" 1/8 (92cm)

C

36" (91cm)

D

17 1/2" (79cm)

E

1

standard 40 5/8" (103cm)

E

2

low profile: 38" (97cm)

E

3

high back , high back w/shelf:

56 1/8" (143cm)

*

* U.S. models only: J=36 1/2”

Clearance Diagrams - 36” Metro

Gas Requirements:
• Gas hook-up must be done by a licensed gas fitter.
• Pressure requirements: Natural gas: 6” W.C. (min); LP
gas: 11” W.C. (min)
• Connection: 1/2”
NPT • 5/8” minimum
diameter flex line.
• An accessible
manual shut off valve
must be installed at
the appliance.
• Natural Gas/Pro-
pane Conversion kits
are available - must
be done by a licensed
gas fitter
Anti Tip Bracket:
bracket included with
every stove. When
properly installed, will
prevent stove from tip-
ping forward if down-
ward force is applied
to an open door.