Clearance diagrams - 30” metro, Dim 30" metro – Heartland 3530 User Manual

Page 8

Advertising
background image

Section 1: Set Up and Assembly

5

Dim

30" Metro

A

1

28 3/4" (73cm)

to front of stove

A

2

31 1/4" (79 cm)

to edge of oven door handle

B

36 1/8" (92cm)

C

29 3/4" (76cm)

D

17 1/2" (45cm)

E

1

standard 40 5/8" (103cm)

E

2

low profile: 38" (97cm)

E

3

high back w/shelf:

56 1/8" (143cm)

Clearances
• Oven door vents must be 2" from any combustible. Door vents are required on Metro units to allow oven door ventilation.
• Minimum distance between the range and a side wall above the cooking top surface is 6” (see dim "O" in Table 2 below)

Electrical requirements:
• Electrical hookup must be done by a licenced electrician
• 240 Volts 60Hz 4.1 kW three prong plug for U.S. and four prong for Canadian installations. (5 ft-1.5 m power cord
included) New installations for the U.S. may require a four prong plug, please confirm prior to ordering.

Gas Requirements:
• Gas hook-up must be done by a licensed gas fitter.
• Pressure requirements: Natural gas: 6” W.C. (min); LP gas: 11” W.C. (min)
• Connection: 1/2” NPT • 5/8” minimum diameter flex line.
• An accessible manual shut off valve must be installed at the appliance.
• Natural Gas/Propane Conversion kits are available - must be done by a
licensed gas fitter

Anti Tip Bracket: bracket included with every stove.
When properly in-
stalled, will pre-
vent stove from
tipping forward if
downward force
is applied to an
open door.

Figure 1

Table 1

Table 2

Figure 2

E dg es of
counter top
m ust be finishe d

G

H

I

J

K

O

cupb
m us
26 ”

o a rd d e pth

t

no t e xce ed

L

M

P

Q

R

S
S

1

N

G as Inlet

A nti-tip
bracket

T

Note: If range must stand
beside a refrigerator, it is
important for proper air
circulation.There must be
at least 5” (125 mm) of
space between the two
appliances.

Dim

30" Metro

G

Maximum 26"" (66cm)

H

36" (92.5cm)

I

10" (25cm)

J

30 3/4" (78cm)

K

5 5/8"(14.5cm)

L

2" (5cm)

M

15" (38cm)

N

10" (51cm)

O

6" (15cm) min left and right side

P

13" (33cm)

Q

SPECIFY WIDTH OF HOOD

R

24" (61 cm)

S

30" min to 36" max (76-92cm)

for standard and high back guard

S

1

30" min to 33-1/2" max (76-85cm)

for low profile back guard only

T

18" (45cm)

* U.S. models only: J=30 1/4”

*

Clearance Diagrams - 30” Metro

For proper performance a 450 CFM vent hood
is required on all 30" Legacy ranges to en-
sure adequate and proper ventilation. For su-
perior ventilation we recommend using a 36”
hood, how- ever a 30” hood is adequate.