Diagnostic tools 83

IMPORTANT: A power interruption during the BIOS update/recovery process can corrupt the system

BIOS code. Make sure the server is connected to a UPS unit during the update process.

To perform a BIOS update/recovery:

1.

Go to http://www.hp.com/go/support and download the System ROMPaq Firmware Upgrade
Utility for your ProLiant server.

2.

Use the ROMPaq Diskette Creator to create a bootable ROMPaq diskette which should contain
the following files:

CONFIG.sys

CPQO2202.xxx

CPQSRVR2.cpu

ROMPAQ.exe

3.

Insert the bootable ROMPaq diskette you created in a USB floppy drive.

4.

Perform the pre-installation procedure.

5.

Remove the PCI riser board assembly.

6.

Locate the boot block jumper on the system board.

7.

Remove the jumper block.

8.

Connect the USB floppy drive with the bootable ROMPaq diskette to your ProLiant server.

9.

Perform the post-installation procedure.
Once you power on the server, it will boot from the USB floppy drive and automatically execute
BIOS update/recovery. The process will take approximately 20 to 30 minutes. When the USB

floppy drive activity LED stops blinking, the process is complete.

10.

Disconnect the USB floppy drive from the server.

11.

Repeat steps 4 through 6.

12.

Return the jumper block to its default 1-2 position.

13.

Perform the post-installation procedure.

Recording custom Setup values

Keep a record of the custom Setup values you have set up for your system BIOS. If the custom values

ever need restoring (after a CMOS clear, for example), you must run the Setup Utility and enter these

custom settings again. Make sure to update this record whenever you make any change to these

Setup settings or install new hardware.

To manually record the custom Setup values:

1.

Access the Setup utility.

2.

Go through each menu and submenus page, and press Print Screen to make a hard copy.

3.

For multiple page menus, move to each page and print each screen.
If a printer is not available, write down the values on a piece of paper. Make sure to write them
down legibly and accurately.

4.

Label and date the Setup values hard copy, and then store it in a safe and accessible place,

preferably with other user documentation for your ProLiant server.