CHAPTER 16

Content Management Application (CMA)

DL.2 Digital Light User Manual

207

To select a DMX Protocol type:

1. Scroll down the Configuration list in the right pane and

double click on the line with DMX Protocol in the Name
column to bring up the edit dialog box.

2. Choose Standard, Dual, or Single from the drop

down list in the option field.

Protocol Selection

DMX Channel Range

Axon

DL.2

Standard Protocol

149

170

Dual Protocol

111

132

Single Protocol

73

94

To edit the DMX Start Channel:

1. Scroll down the Configuration list in the right pane and

double click on the line with Start Channel in the Name
column to bring up the edit dialog box.

2. Enter a valid Start Channel for the protocol type you

have chosen. For more information on selecting a valid
start channel, see Determining a DMX Start Channel on
page 38
.

Configuration Options

Available configuration values will depend on whether
you’re viewing an Axon or a DL.2 media server. The following table shows the configuration
values available for viewing and/or editing.

NOTE: Read Only options are for information display only and cannot be

edited. If you select or type in an option that is invalid, the OK button

will be grayed out and not selectable.

DL.2 Configuration Options

Configuration Item

Configuration Value Options

Art-Net Subnet

0-16

Art-Net Universe

0-16

Box Current Temperature

Read only

Box Maximum Temperature

Read only

Box Minimum Temperature

Read only

Box Temperature Reset

Pressing Reset restores value to Current Temperature

CPU Current Temperature

Read only

CPU Maximum Temperature

Read only

CPU Minimum Temperature

Read only

CPU Temperature Reset

Pressing Reset restores value to Current Temperature