Cleaning the base housing filter, Replacing the fixture filter – High End Systems DL.2 User Manual

Page 235

Advertising
background image

CAUTION!
Do not operate a projector with Air Filter removed. Dust may
accumulate on LCD Panel and Projection Mirror degrading

projection quality.
Do not put small parts into Air Intake Vents. It may result in
malfunction of a projector.

CHAPTER 17

Maintenance and Troubleshooting

DL.2 Digital Light User Manual

213

Cleaning the Base Housing Filter

This filter is located between
the handles on the fan side of
the box. You can pull it off the
fixture and clean it with soap
and water. Allow it to dry
thoroughly before replacing.

Loosen

Top cover

Filter bracket

Filter

Rear Bezel

Open Latches

Tilt lock

Remove

Pull base housing filter away

Pre-filter

turn screws

top cover

philips screws
and lift filter
bracket

to remove
bezel

from fixture to clean

Quarter-

to remove

Replacing the Fixture Filter

A hepa filter and a prefilter are
located inside the fixture head
and should be replaced when-
ever they become discolored
from particulates or when the
Menu displays FILTER Service
ERROR
or FILTER Service
WARN

Access the fixture filters

1. Lock the fixture head in the

70

°

tilt position.

2. Unlatch and remove the

rear bezel assembly.

3. Loosen the two quarter-

turn screws on the top
cover and remove the top
cover.

4. Slide the top cover back to free it from the front bezel.

Inspect the filters:

5. Lift the prefilter away from the filter bracket

6. Remove the two philips pan screws securing the filter bracket and lift the filter unit off the

fixture.

7. Remove the bracket and lift the HEPA filter out of the filter housing. Inspect both the

prefilter and the HEPA filter.

8. A dirty prefitler can cause an early Service Filter warning. If the prefilter looks dirty, clean it

with water. Thoroughly dry the prefilter before proceeding.