Evaporator Placement

Figure 3. Evaporator Placement In Cooler/Freezer

Typical Layouts for Illustration

(refer to build plans for actual room layout and equipment location)

The ADT/LET units are draw through units. For best operation, they should be located away from entry

doors and at least 18” from the wall with the fans blowing into the room. Make sure the units are flush

mounted to the ceiling to insure proper drainage for defrost water.

H = Total
height of
unit coil
surface.

Always avoid placement of Unit Coolers
directly above doors and door openings
where low temperature is being
maintained and wherever possible for
medium temperature.

NOTE:

NOTE:

Whenever possible, always try to position
the evaporator to blow towards the vault
door. Never position it over or adjacent to
a door opening.

Elevation view of glass display
door cooler or freezer. Be sure air
discharge blows above, not directly
at doors. Provide baffle if door
extends above blower level.

1 H

1_ H

1 H

1 1/2 H

1 1/2 H

1 1/2 H

1 1/2 H

1 1/2 H

1 1/2 H

1 1/2 H

3 H