3-2. COOK CYCLE

PROGRAMMING
(Continued)

10. Follow steps 4, 5, and 6 until all six intervals have been

programmed for pressure.

The above steps may be followed for interval alarms
except you cannot program an interval alarm in the
first interval.

Refer to Special Programming Modes on factory
presets for load compensation, proportional control,
and filter cycle counts.

3-3. ERROR CODES

The following defines the error code number. If an error code
occurs, the buzzer will sound until you depress a cycle switch.
The control will continue to display the error code and fryer
will be inoperative until error is corrected.

• E 5 - Pot temperature too high. (Software high limit)

• PROB - Temperature probe has failed.

• E 41 - Control Problem - Must be initialized and

reprogrammed.

3-4. SPECIAL

PROGRAMMING MODES

The special programming modes are entered by way of a
special sequence of keys and are intended to be infrequently
used for service or factory preset functions. The modes are
numbered according to the cycle that is selected to enter them.

• KFC Parameters (Factory Preset) (Cycle 6)

• Test Procedures (Cycle 7)

To enter special programming mode, the following steps must
be followed exactly.

1. Enter the password keystroke sequence for programming

mode. Refer to “The Basic Programming Sequence”.

2. Depress the EXIT COOL switch. Display will read “SP”.

3-2