3-4. SPECIAL

PROGRAMMING MODES
(Continued)

3. Select the desired special function by depressing either

cycle switch 6 or 7.

4. Perform the desired operation.

5. Depress the EXIT FILL switch to exit the special program

mode. Unit will return to stand-by cook mode.

The preceding steps must be followed exactly to enter
the special program mode.

3-5. ONE STEP KFC

PARAMETERS

1. Enter the special program mode.

2. Depress the cycle 6 switch. Display will read as follows.

Digit

4

3

2

1

Digit 1: Blank - When depressed it will erase all memory from
controller. Display will read INIT for one second then erase
all memory.

Digit 2: Blank - When depressed it will enter all KFC cooking
parameters. Display will read INIT for two seconds, then DEF
for two seconds.

Digit 3: Display will read either F for Fahrenheit degrees or
C for Celsius degrees.

Digit 4: Display will read either E for Electric or 0 for other
(includes gas).

3-6. TEST PROCEDURE

1. Enter the special program mode.

2. Depress the cycle 7 switch. Display will be blank.

3. Depressing a certain switch on the front panel turns an

output on, while depressing the same switch again turns
that output off. This will test all circuits on the controller.