Henny Penny FM07-020-F User Manual

Page 22

Advertising
background image

3-6. TEST PROCEDURE

(Continued)

The table below shows the corresponding switch with the
output.

Switch

Device Activated

Product One

Pressure Solenoid and Heat Control

Select Time

Product Indicators

Select Function

Function Indicators

Change Switch Under Display 4

Change Switch Indicator Display

Change Switch Under Display 3

Change Switch Indicator Display

Change Switch Under Display 2

Change Switch Indicator Display

Change Switch Under Display 1

Change Switch Indicator Display

The SELECT FUNCTION or SELECT TIME switch
must be depressed before the PRODUCT ONE switch
to properly perform the solenoid and heat control
output test.

To avoid personal injuries or property damage when
performing the solenoid and heat control test, be sure
there is shortening in the frypot. Unit will run
unregulated. For test purposes only.

3-7. SPECIAL FUNCTIONS

When programming one step KFC parameters, load compen-

sation, proportional control, and filter cycle are automatically
programmed into the control. The following defines these three
functions.

Load Compensation - Load compensation adjusts cooking

times to compensate for differences in the cooking process such
as load size. The control is continuously comparing the pot
temperature to the setpoint, the control will shorten the cook time.
If the pot temperature is below the setpoint, the control will
lengthen the cook time. Load compensation for KFC
parameters is set at 0.

Proportional Control - Proportional control regulates pot tempera

ture by pulsing the heat off and on until it reaches setpoint tempera
ture. This allows better temperature accuracy when dropping
product. Proportional control for KFC parameters is set at
10 degrees.

Filter Cycle - Filter indication is given after the programmed

number of cycles are cooked. KFC parameters are set at 1,
and further operation of the control is not allowed until filtering
is complete.

3-4

304

Advertising