1-3. INTRODUCTION

Installation of the KFC Computerized Control Panel on existing
Henny Penny gas pressure fryers.

Disconnect the fryer from the electrical supply source
before beginning panel conversion.

Failure to disconnect the fryer from the supply source
could result in electrical shock.

The fryer internal wiring is numbered to correspond to the
numbers on the wiring diagram, Figure 1.

1-4. CONTROL PANEL WIRE

REMOVAL

A. Remove the four screws holding the existing control panel in

place.

B. Position the control panel for servicing by placing the lower

edge of the control panel on top of fryer frame and door.

C. Identify the locations of the following wires. Reference wire

diagram Figure 1.

Wire

Wire Number

Pin Number

Location

9 Pin Conenctor

Neutral

2

1

Main Power Switch

Motor

34

9

Main Power Switch

Motor

33

7

Main Power Switch

L 1

1

3

Main Power Switch

Fan

10

4

Main Power Switch

Solenoid

31

6

Main Timer

Solenoid

32

8

Soft/Crisp Switch

Hi Limit & Fan

8

2

Wiring Harness

Gas Valve

12

5

Gas Valve

1-2