1-7. SLOT COVER

When installing the computerized panel retrofit kit, it is necessary
to cover the existing slot in the heat shroud. This slot allows the
capillary tube of the old control panel to extend through the heat
shroud when mounting the old control.

A. Open door and push slot cover through shroud from bottom

of the shroud.

B. Bend the 4 tabs of slot cover over the top of the heat shroud.

1-8. CONTROL PANEL

INSTALLATION

A. The new computerized panel is positioned and installed exactly

like the existing electromechanical control panel.

B. Place the computerized control panel on top of fryer frame

and door.

C. Mate the nine-pin connectors together. Refer to KFC gas

wiring diagram.

D. Connect the temperature probe to the control panel board.

E. Install the control panel and two screws. When installed

properly there will be approximately a 7/16 inch of a gap
between the bottom of the control panel and fryer rail.

F. This completes the electrical and mechanical installation of

the computerized control panel.

1-4