venting Installation

Chimneys taller than 20’ above the connection will

require a draft test to determine if the draft is too high.

Note: The high burn draft should not exceed .85 IWC.

Some form of a restrictor plate may be required at the

top of high chimneys to reduce the draft. See page 21

for the Draft Test procedure.

Creosote - Formation and Need for Removal - When wood is burned slowly, it produces tar and other organic vapors,

which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue

of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an

extremely hot fire. The pellet vent pipe should be inspected at least twice monthly during the heating season to determine

if a creosote buildup has occurred. If creosote has accumulated it should be removed to reduce the risk of a chimney fire.

Guidance on minimizing creosote formation and the need for periodic creosote removal: The chimney should be

inspected during the heating season to determine if a creosote build-up has occurred. If a significant layer of creosote has

accumulated (3mm or more) it should be removed to reduce the risk of a chimney fire.

This boiler may be used and installed into an existing

masonry or Class A metal chimney.

Certain Canadian and Local Codes may require that

the chimney be fully relined.

The venting Can Not be installed in a chimney serv-

ing another appliance.

The chimney should be cleaned and or inspected before

installation of the venting.

NOTE: All installation clearances and restrictions

must be adhered to.

NOTE: Read and follow all of the vent pipe

manufacturers’ instructions on the proper

installation and support of the vent pipe. Adhere

to all clearances.

DO NOT INSTALL A FLUE DAMPER IN THE

EXHAUST VENTING SYSTEM OF THIS UNIT.

DO NOT CONNECT THIS UNIT TO A

CHIMNEY FLUE SERVING ANOTHER

APPLIANCE.

INSTALL VENT WALL PASS-THROUGHS AT

CLEARANCES SPECIFIED BY THE VENT

MANUFACTURER

INSTALLATION IS TO BE PERFORMED BY

A QUALIFIED INSTALLER.

NOTE: Use only 4” diameter approved pellet

venting system. Be sure to inspect and clean

exhaust venting system frequently.

KEEP COMBUSTIBLE MATERIALS SUCH

AS GRASS, LEAVES, ETC. AT LEAST 3 FEET

AWAY FROM THE POINT DIRECTLY UNDER

THE VENT TERMINATION. (BETWEEN THE

VENT AND THE GROUND)

WARNING

KEEP COMBUSTIBLES AWAY

FROM FLUE OUTLET.

CAUTION