Installation

Draft Bolt Location

Viewing Window

Air wash Slot

Firebox Door

Fig. 9

“Test”

Low Draft

Adjustment Pot

Fig. 10

Fig. 11

Covered

Un-Covered

Air Wash Slot

Draft Test Procedure

After the venting is completed, the firebox low draft

will need to be checked and possibly adjusted. After

removing the 3/8” bolt from the draft hole shown in Fig.

9, insert the draft meter tube. The appliance doors and

hopper lid must be latched during this test. (It is recom-

mended that the draft meter have a scale of 0 to 1” WC.)

Turn the feed adjuster to “Test”. this will start the

combustion blower and allow you to check and record

the High Draft ______ - IWC date _______ The

maximum draft must not exceed -.85” W.C. Some form

of vent restrictor may be needed. (There is no control

board adjustment for the High Draft)

After the first 60 seconds the “Test” mode lowers the

combustion blower voltage to the Low Burn voltage.

During this lowered voltage cycle the Low Burn Draft

must be checked and adjusted if necessary. The recom-

mended low draft setting should be between -.25 & -.35

IWC. Depending on the amount of vertical rise, it may

not be possible to get a low draft reading in this range.

In this case, a maximum low draft of -.55 is acceptable.

The adjustment screw is through the small hole to the

right of the Igniter Light. See Fig. 10

.

Adjusted Low

Draft is __________ -IWC.

Don’t forget to turn the feed adjuster off of “Test”.

Do not operate if the high draft exceeds -.85” W.C.
Excessive draft readings may be due to restriction in

the combustion air supply. Check for obstructions.

The Control

The boiler has the option to have the control panel

covered or un-covered See Fig. 11. There is a pair of

slots provided for each position. Simply move the cover

to the desired position by placing the tabs on the cover

in the proper slots.

WARNING: Do not operate with the hopper

lid or fire chamber or ash removal doors open.

WARNING: Do not store fuel or other

combustible material within installation

clearance area.

CAUTION: Hot while in operation. Do not

touch. Keep children, clothing, furniture,

and other combustible material out of the

installation clearance area.