Installation, Example #1 example #2 – Heatiator Heatilator BH60 User Manual

Page 17

Advertising
background image

17

NOTE: ALWAYS REFER TO THE INDIVIDUAL COMPONENTS
RECOMMENDED INSTALLATION INSTRUCTIONS FOR THE PROPER
MOUNTING POSITION AND LOCATION WITHIN THE PIPING SYSTEM.

HIGHER TEMPERATURE
WATER (IF NEEDED)

NOTE: TYPICALLY, AS LONG AS THE WATER
TEMPERATURE NEEDED IS NOT MORE THAN
120 F, THE MIXING VALVE SHOWN ABOVE
(EXAMPLE 2) IS NOT NEEDED

EXAMPLES OF TYPICAL DOMESTIC HOT WATER STORAGE PIPING

IN

TO BOILER

OUT

FROM BOILER

CIRCULATOR

COLD

HOT

DOMESTIC HOT
WATER STORAGE
HEATER

OUT

IN

TO BOILER

HOT

DOMESTIC HOT
WATER STORAGE
HEATER

COLD

FROM BOILER

CIRCULATOR

MIXING VALVE

EXAMPLE #1

EXAMPLE #2

MIXING VALVE SET TO DESIRED WATER TEMPERATURE.
NORMALLY NOT MORE THAN 120 DEGREES.

TEMPERED HOT WATER FOR
SHOWERS AND FAUCETS

Installation

COLD WATER SUPPLY

MIXING VALVE SET TO DESIRED WATER TEMPERATURE.
NORMALLY NOT MORE THAN 120 DEGREES.

FLOW REGULATOR WILL NEED TO MATCH THE GPM RATING OF THE DOMESTIC COIL. (IF USING A DOMESTIC COIL, 4 GPM IS REQUIRED.)

HOSE BIB TO
BACKFLUSH COIL
IF NEEDED

AQUASTAT WELL LOCATION

HOSE BIB

SAFETY RELIEF VALVE

FLOW REGULATOR

ISOLATION VALVE

NOTE: ALWAYS REFER TO THE INDIVIDUAL COMPONENTS
RECOMMENDED INSTALLATION INSTRUCTIONS FOR THE PROPER
MOUNTING POSITION AND LOCATION WITHIN THE PIPING SYSTEM.

EXAMPLE OF TYPICAL TANKLESS DOMESTIC HOT WATER PIPING

OUTLET

OPTIONAL DOMESTIC
HOT WATER COIL

INLET

MIXING VALVE

HIGH TEMPERATURE
WATER (IF NEEDED)

TEMPERED HOT WATER TO
SHOWERS AND FAUCETS