31

maintenance

Fig. 21

Ash Door Handle

Ash Door

Ash Pan

Ash Pan Handle

Ash Removal

It is recommended to remove the ashes when the boiler

is not in operation. This lessens the chances of coming in

contact with hot surfaces. Ashes can be removed while

in operation but, extra care must be taken.

Open Ash Door

Lift the latch and open the door as shown in fig. 21.

Disposal of Ashes

Ashes should be placed in a steel container with a tight

fitting lid. The closed container of ashes should be moved

outdoors immediately and placed on a non-combustible

floor or on the ground, well away from all combustible

materials, pending final disposal. If ashes are disposed

of by burial in soil or otherwise locally dispersed, they

should be retained in the closed container until all cinders

have thoroughly cooled. Other waste shall not be placed

in this container.

Soot and Flyash: Formation and Need for

Removal

The products of combustion will contain small particles

of flyash. The flyash will collect in the exhaust venting

system and restrict the flow of the flue gases. Incomplete

combustion, such as occurs during startup, shutdown,

or incorrect operation of the room heater will lead to

some soot formation which will collect in the exhaust

venting system. The exhaust venting system should be

inspected at least twice monthly to determine if cleaning

is necessary. Pay particular attention to screening in the

vent cap. The screen, if present, will accumulate with

ashes rather quickly.

Remove Ash Pan

Always wear gloves to remove ash pan. Grab the ash

pan by the finger hold and pull it out of the boiler. Lift

the ash pan by the finger hold and use it for carrying the

ash pan. Close the ash door before disposing the ashes.

NOTE: Keep hopper lid, hopper swing plate, firebox

door and ash pan door closed during operation and

maintain all seals in good condition.

WARNING! RISK OF FIRE!

• Ash, soot or creosote build-up may cause

overheating or fire.

• Routine cleaning of heat exchangers and

venting is required.