Outside Air

To install outside air, use 2 3/4” I.D.galvanized

steel flex pipe, part # 2-00-08544 ( 12’ 6” length) or part

# 2-00-08545 ( 25’ length) See Fig. 6. There is a break-

away hole on the rear panel which must be removed

before connecting the flex pipe. See Fig. 7.

When the appliance is side wall vented: The air

intake is best located on the same exterior wall as the

exhaust vent outlet, and located lower on the wall than

the vent outlet.

When the appliance is roof vented: The air intake

is best located on the exterior wall oriented toward the

prevailing wind direction during the heating season.

Never terminate the outside air above the vent pipe

outlet. The maximum length of this pipe is 20 feet. Inlet

cover part number 1-10-09542 should be used to keep

birds, rodents etc.out of the inlet pipe. See Fig.6.

NOTE: The inlet cover should not be placed in an

area where drifting of snow or ice will build up, block-

ing the intake air supply.

The Outside Air knockout is located on the face of

the Feeder Cover. It is pre-cut except for several small

tabs. There is also a filler plate screwed to the inside

to cover the top of the hole after the Outside Air Pipe

has been installed. This will allow for removal of the

Feeder Cover without disconnecting the Outside Air

Pipe. See Fig. 7.

Only metal Intake Flex should be used for the

Outside Air Supply connection.

The Outside Air Intake Pipe is inside the Feeder

Cover and to the right of the feeder motor. The 2 3/4”

steel flex pipe is made to slide over the outside of the

Air Intake Pipe.

See Fig. 8. It should be held into place

with some silicone, foil tape, or a hose clamp. (not

supplied)

Heat Reclaiming Ventilation System (HRV)

When installing in a house with a Heat Reclaim-

ing Ventilation System (HRV) be sure the system is

balanced and is not creating a negative pressure in the

house.

Inlet Cover part#

1-10-09542

Installation

Fig. 6

Fig. 7

Fig. 8

Outside Air Pipe

Knockout

Feeder Cover

Hopper/Feeder

Swing Plate

Knob

Outside Air Inlet Pipe