main wiring Installation

To install power to the boiler

, first remove the cover on the 4” X 4” junction box located on the back of the unit.

There are several knockout

holes provided for the incoming main power wires.

Also, a knockout hole can be used for the auxiliary output overheat zone (if used).

The minimum recommended circuit is 6

AMP

- 120

VAC - 60 HZ.

This boiler should be the only appliance on the circuit.

This boiler

should never

be power

ed by the use of an extension cord.

The recommended high and low voltages are, 130

V.A.C. 60 Hz maximum high voltage, and 1

13

V.A.C. 60 Hz minimum low voltage.The furnace will

continue to operate at voltages as low as 105

V.A.C. , although it can not be guaranteed that automatic ignition will occur

.

NOTE: If other

sour

ces of electrical

power

ar

e to be used ( such as a generator

) for

normal operation or

emergency

operation, this sour

ce

should be checked

befor

e

installation.

Many generators and inverters

may not supply 120V

.A.C. 60Hz.

power

stable enough to operate

the contr

ol

board pr

operly

. (Contr

ol board damage could occur).