2. VERTICAL TERMINATION

a. Clearances

See Figure 13 for clearance information.

b. Vent Lengths

Various venting configurations are shown in

Figures 14 and 15 from which the maximum vent

runs can be determined.

Figure 13

Vent Clearances

Figure 14 - Vent Lengths

Figure 15

Vent Support

WARNING!

A gas appliance must not be connected to a chimney

flue servicing a separate solid fuel burning appliance.

WARNING - RISK OF FIRE!

Always maintain minimum clearances or greater

around the chimney system. Do not pack air spaces

with insulation or other material.

WARNING!

The horizontal run of vent must have a 1/4” rise for

every 1’ of run towards the termination. Never allow

the vent to run downward. This could cause high tem-

peratures and present a fire hazard.