H. utilities, Access panel, Btus – Heatiator Heatilator BCDV36 User Manual

Page 15: Conversion kits, Conversions, Fuel, Fuel conversions, Pressure, Gas line connection, Input rate

Advertising
background image

01-03

15

33606 Rev D

BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS

H. UTILITIES

1. GAS LINE CONNECTION

Open the control access panel as shown in Figure 24.

See Figure 25 to connect the gas line properly. All

connections must be checked for leaks with a soap

and water solution or a leak detector. Bleed the gas

line to extract any air that may have been trapped inside

the pipe.

This appliance is supplied with a 3/8” flare connection

to the gas valve. Installation of flexible connector and/

or manual gas valve must conform to local codes. In

the absence of local codes, with the National Flue Gas

Code ANSI Z223.1-latest edition in the U.S.A. and the

CAN/CGA B149 Installation Codes in Canada.

This appliance has been tested for installation of a

manual shutoff valve in the bottom compartment of the

appliance.

The Commonwealth of Massachusetts requires this

to be a T-handle type manual shutoff valve.

Note:

This appliance and its manual shutoff valve must

be disconnected from the gas supply piping system dur-

ing any pressure testing of that system at test pressures

in excess of 1/2 psi (3.5 kPa). The appliance must be

isolated from the gas supply piping system by closing its

manual shutoff valve during any pressure testing of the

gas supply piping system at test pressures equal to or

less than 1/2 psi (3.5 kPa).

2. GAS PRESSURE

On the standing pilot gas control valve, a pressure tap

is included on the front face of the valve.

Table 2 shows the optimum gas pressure information.

Consult your local gas company for assistance in

determining the proper orifice for your altitude or refer

to ANSI Z223.1 - latest edition.

Table 2 - Gas Information for Standing Pilot Appliances

Figure 26 - Conversion Kit

6

3

V

D

C

B

.

G

.

N

.

P

.

L

f

o

e

s

o

p

r

u

P

r

o

f

e

r

u

s

s

e

r

P

t

e

l

n

I

m

u

m

i

n

i

M

t

n

e

m

t

s

u

j

d

A

t

u

p

n

I

*

5

.

4

*

1

1

e

r

u

s

s

e

r

P

t

e

l

n

I

m

u

m

i

x

a

M

*

5

.

0

1

*

4

1

e

r

u

s

s

e

r

P

d

l

o

fi

n

a

M

l

a

m

it

p

O

*

5

.

3

*

0

1

e

r

u

s

s

e

r

P

d

l

o

fi

n

a

M

m

u

m

i

n

i

M

*

7

.

1

*

4

.

5

H

/

U

T

B

t

u

p

n

I

m

u

m

i

x

a

M

0

0

0

,

0

2

0

0

5

,

8

1

s

e

h

c

n

I

-

e

z

i

S

e

c

if

ir

O

9

8

0

.

0

2

5

0

.

0

n

m

u

l

o

C

r

e

t

a

W

f

o

s

e

h

c

n

I

*

Figure 24 - Control Access Panel

Figure 25 - Gas Line

Optional: Seal around the gas line to prevent cold air leakage.

(Right Side)

3. GAS CONVERSIONS

Natural or propane gas conversions necessary to meet

the application need to be made by a qualified

technician using Hearth & Home Technologies

specified and approved parts.

In the event your appliance must be converted to use

propane, you must use a CKP Conversion Kit. To be

converted to use natural gas, you must use a CKN

Conversion Kit. See Figure 26.

WARNING!

This valve has been preset at the factory. Altering

settings may result in fire hazard or bodily injury.

Advertising