C. location and clearances, Minimum venting, Location and clearances – Heatiator Heatilator BCDV36 User Manual

Page 6: Space requirements, Builder's choice series installation instructions

Advertising
background image

33606 Rev D

6

01-03

BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS

C. LOCATION AND CLEARANCES

1. APPLIANCE LOCATIONS AND SPACE

REQUIREMENTS

Figure 1 illustrates a variety of ways the appliance may

be located in a room. The Builder's Choice Series may

be installed directly on the floor or on a hearth. These

appliances are certified for installation in a bedroom,

bed/sitting room or in mobile homes in the U.S. and

Canada.

2. CLEARANCES

a. For the appliance:

Top of standoffs

Floor

Back of appliance

1/2”

Sides

1/2”

Front Face to Ceiling

30”

b. Minimum Venting Clearances (see Figure 2).

1) Horizontal runs off of the back of the

appliance to the wall shield:

0” above the top of the appliance standoffs

1” sides and bottom of the vent

2) Horizontal runs inside a wall (heat shields

must be installed)
3” air space on top of the vent

1” from sides and bottom of vent

3) Vertical runs

1” air space around the vent

Figure 1 - Appliance Locations

Note:

Dimensions represent minimum space required

for a centered corner installation. Actual requirements

will vary with individual construction.

Figure 2 - Rear Vented Appliances Venting Clearances

WARNING!

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Dimensions