BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS

1. ATTACHING THE VENTING TO THE

APPLIANCE

To attach the first VP section to the appliance collars,

simply slide the flared end of the inner vent of the VP

section over the inner collar on the appliance. At the

same time, insert the outer vent into the outer collar

on the appliance. Push the vent section into the

appliance collar until all the lances have snapped in

place. Tug slightly on the vent to confirm it has

completely locked into place.

2. ASSEMBLING VENT SECTIONS

a. Start the flared inner flue of section “A” over the

inner flue of section “B”.

b. Insert the outer flue of section “A” into the outer

flue of section “B”. See Figure 19. Once both inner

and outer flues are started, press section “A” into

section “B” firmly until all lances have snapped

into place. Tug slightly on section “A” to confirm it

has completely locked into place. See Figure 20.

Note:

Squeezing the pipe slightly to fit may be

necessary.

Note:

Make sure that the seams are not per-

fectly aligned to prevent unintentional discon-

nection.

Figure 19

Figure 20

Figure 21

3. ASSEMBLING MINIMUM INSTALLATIONS

(MI) SECTIONS

MI sections are non-unitized so that they can be cut to

a certain length. To use these sections, they must be

cut to length from the non-expanded end. See Figure

21. They can then be attached by first connecting the

expanded end of the MI inner vent with the inner vent

from the adjacent vent section and securing with three

screws. The expanded portion of the MI inner vent must

overlap completely with the untreated end of the

adjacent vent section. The outer vent can then be

inserted into the adjacent outer vent expanded end

and attached to the next vent section with three screws.

The other end of the MI vent section can then be

attached by fitting a snap lock section to it and snapping

it together as normal.

G. ASSEMBLING VENT SECTIONS