None, Builder's choice series installation instructions – Heatiator Heatilator BCDV36 User Manual

Page 9

Advertising
background image

01-03

9

33606 Rev D

BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS

c. No Elbows

The maximum horizontal run with no vertical

sections of vent is 18” from the back of the

appliance to the base of the cap. See Figure 7.

d. A 45° Elbow

For corner venting, a maximum of one 45° elbow

may be used. The maximum horizontal run

following the elbow is 12” to the base of the cap.

See Figure 8.

Figure 7

Rear Vented Appliances

Figure 8

One 45° Elbow

Figure 9

Two Elbows

e. Two Elbows

Figure 9 shows various venting configura-

tions using two elbows to terminate horizon-

tally. The maximum vertical run is 20’ and the

maximum horizontal run is 14’.

f.

Three Elbows - One Elbow Horizontal
Figure 10 shows various venting

configurations using three elbows to

terminate horizontally. The maximum vertical

run is 20’ and the maximum horizontal run is

12’.

Figure 10

Three Elbows

Advertising