Electric, Electric codes, Junction box – Heatiator Heatilator BCDV36 User Manual

Page 16: Standing pilot ignition, Standing pilot wiring diagram, Wall switch, Wiring, Builder's choice series installation instructions

Advertising
background image

33606 Rev D

16

01-03

BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS

Figure 27

Standing Pilot Ignition Wiring Diagram

14-3 with Ground Romex is the recommended

wiring to the appliance Junction Box.

Detailed picture of the Junc-

tion Box (Optional for Stand-

ing Pilot Appliances).

4. WIRING

Standing Pilot Ignition - Millivolt System

a. Appliance Requirements

A wiring diagram is shown in Figure 27.

b. Wall Switch

The installer shall supply UL or in Canada, CSA-

listed wall switch and wiring between appliance

and wall switch. This appliance was tested with

eighteen feet of UL Listed 18 ga. Type CL2 105°C,

two conductor “thermostat wire.” If other wiring

materials are used they shall comply with local

codes or in the absence of local codes, with

National Electrical Code ANSI/NFPA 70-latest

edition or Canadian Electrical Code CSA C22.1.

c. Optional Accessories Requirements

Wiring for optional accessories should be done

now to avoid reconstruction.

5. JUNCTION BOX INSTALLATION AND

WIRING

Refer to the installation instructions included with the

JK9 Junction Box Kit and the insert of Figure 27.

Note:

This appliance must be electrically wired and

grounded in accordance with local codes. In the absence

of local codes, the wiring must comply with the National

Electric Code ANSI/NFPA 70 - latest edition or the

Canadian Electric Code CSA C22.1.

WARNING!

This standing pilot appliance does not require a 110V

AC power supply for operation. Connecting the appli-

ance/wall switch to a 110V AC will cause the appli-

ance to malfunction and destroy the valve and ther-

mopile.