2–14

SCANTEAM 5700 User’s Guide

Data Format Editor

This selection provides editing of all input (scanned) data. All Industrial and
Retail symbologies can be formatted. You may scan the Clear Data Format bar
code if you are certain you want to delete or clear all formats.

Use the Data Format Editor by following the steps below:

➊ Scan the Enter Data Format bar code.
Terminal Type

Scan two bar codes that represent the terminal type (00-99

[, see page

1–11 for Terminal I.D. list.)

Code I.D.

Refer to the Symbology chart (page 2–7), then scan two bar codes from
the “Hex Value” column that represent the Code I.D. of the symbology you
want formatted. (“All Symbologies” – hex value 99 – is not supported by
Data Formatter.)

Length

Scan two numeric bar codes (inside back cover) for the bar code length you
require (00-99

[). Be sure to include spaces.

To make Data Format Editor selections, you must know the terminal type,

code I.D., code length, and editor commands your application requires.

Use the Alpha-numeric bar codes (inside back cover) to scan these

options.

Editor Command Sequences

Refer to the Format Editor Commands chart (page 2–16). Scan two bar
codes that represent the command you need.

End Format (FF)

Scan “F” twice to end Data Format Editor programming.

[ 99 is the Universal number, indicating all terminals and all code lengths.