Hand Held Products 5700 User Manual

Page 41

Advertising
background image

2–17

SCANTEAM 5700 User’s Guide

You are using an IBM PC AT and are scanning a UPC A bar code with a five digit
addenda (shown below). The bar code has a total of 18 characters, including the
number system, the check digits, and a space between the main bar code data
and the addenda bar code data.

Data Formatter Example

H

Scan the Enter Data Format bar code (page 2–15).

H

Scan the 03 bar codes for PC AT Terminal Type.

For your application, you don’t want the space between the main bar code data
and the addenda bar code data transmitted. You also want the bar code data
followed by a carriage return (CR).

UPC A with 5 digit addenda

56098

0 12345 67890 5

Refer to the Format Editor Commands Chart on page 2–16 to format the
following example. The programming bar codes on pages 2–15, and the
alpha-numeric bar codes on the inside back cover are used to program the data
formatter.

H

Scan the 63 bar codes, the Hex value for UPC symbology.

H

Scan the 18 bar codes for the bar code length.

H

Scan the FB (suppress characters command) bar codes, scan 20 (the Hex
value for a space), and then scan FB to frame (complete) the command.

H

Scan the FF bar codes to end Format Editor selection.

The following are the Editor Command Sequences:

H

Scan the F7 bar codes to move the cursor back to the beginning of the bar
code data.

H

Scan the F1 and 0D bar codes to send all the characters followed by a
carriage return (CR= 0D in Hex value).

Advertising