7–3

SCANTEAM 5700 User’s Guide

Laser Output only

5700–X4

(Laser Compatible Bar Image +12VDC Input*)

Conventional laser data format is provided at the modular connector in the
scanner handle.

Signal

Function

Interface cables normally supplied with scanner model 5700–X0 are terminated
with an 10 pin modular plug (P1) and a 9 pin Type D (Squeeze–to–release)
connector (P2) that is compatible with all Welch Allyn terminals. See chart below.

1

3

4

5

6
8

9

1
3
7

8

5
6
9

2

P2

P1

9 Pin Type D Female

10 Pin Modular Plug

Pin 1

Pin 10

6

9

1

5

N/C

Enable

Ground

Good Read

Data

Trigger

SOS

Power Connection

Laser Enable

Supply Ground

Turn on Good Read LED or Beeper

Digital Bar Code Data Output

Trigger Signal to Decoder

Start of Scan

+12VDC

P1

P2

View A–A

P2 connects to

your terminal.

P1 connects to the
scanner handle.

* Note: Cable supports decoders which supply +12V on pin 9 ONLY.

10

VCC (Connected for AutoTrigger**)

** Note: Reference the Cable Matrix for correct AutoTrigger cable.