Rps/eps electrical input, Environmental, Btu ratings – HP PROCURVE 2610 User Manual

Page 82

Advertising
background image

A-2

Switch Specifications

S

w

itc

h

Sp

e

c

ific

a

tio

n

s

RPS/EPS Electrical Input

Environmental

*

The operating maximum altitude should not exceed that of any accessory being connected

to any switch in the 2610 series.

BTU Ratings

2610 Non-PWR Series

Input voltage

Maximum current

RPS Input

+12 VDC

7.5A

EPS Input

N/A

N/A

2610-PWR Series

Input voltage

Maximum current

RPS Input

+12 VDC

7.5A

EPS Input

-50 VDC

16A

2610 Switches

Operating

Non-Operating

Temperature

0

°C to 50°C (32°F to 122°F)

-40

°C to 70°C (-40°F to 158°F)

Relative humidity
(non-condensing)

15% to 95% at 40

°C (104°F)

15% to 90% at 65

°C (149°F)

Maximum altitude

3.0 Km (10,000 ft)*

4.6 Km (15,000 ft)

Switch Model

Combined BTU

1

Switch only BTU

2610-24/12PWR

827

181

2610-24-PWR

2281

410

2610-48-PWR

2281

410

2610-24

Non-PoE

142

2610-48

Non-PoE

285

1

Includes switch and maximum number of PoE powered devices

connected to the switch at 15.4 watts.

Advertising