SK-91F467-FLEXRAY V1.1

Jumpers and Switches

© Fujitsu Microelectronics Europe GmbH

- 37 -

FMEMCU-UG-910017-11

JP57 Select which UART should do the system reset

JP29 The polarity of the DTR/RTS signal can be inverted by this jumper. Remove the

jumper to disable the UART reset function

Jumper

Setting

Description

1-2

Reset will be done via UART2

3-4

Reset will be done via UART4

JP57

5-6

Reset will be done via UART5

1-2

No polarity inversion for the DTR/RTS signal

JP29

2-3

Polarity inversion for the DTR/RTS signal

Table 3-24: Reset UART Selection

By default the UART reset is disabled.

Note:
During normal operation, the reset LED should be off!

If the reset LED is steadily on, check the power supply
voltages and the settings for the reset generation by UART.